66FW53H DA100 Repair Tips
Search: 66FW53H DA100
Results 3
Results 3
Make | Model Ch. | Symptom | Problem Solution | Solution | By: |
---|---|---|---|---|---|
Sharp | 66FW53H DA100 | Failure of Q601 BUH515 and possibly Q506 | Found dry joints on C613. Also R613 had burnt top of C613. Fitted new parts, found Circuit no longer available. Sharp by name sharp by nature came to mind. Set only just over two years old | ||
Sharp | 66FW53H DA100 | Dead | IC 705 RH-FX0110BMZZ, CNY17F-2; C720 RC -EZ0258CEZZ, 100UF 200V; D735 RH-EX0875BMZZ DIODE AVALANCHE; D712 RH EX0419BMZZ, DIODE15 ZENER; Q701 RH-TX0198BMZZ S5410N80A ; Q702 RH-TX0182BMZZ 2PD602AR[s.m.]; Q703 RH-TX0151BMZZ 2SD2391Q [s.m.] | ||
Sharp | 66FW53H DA100 | Constant trip | Bypassing prot (s/c pin 15 IC702 to chassis) brought pic on with limited functions - sm NVROM chip faulty & adj geometry settings (maunual reqd) |